What temperature should a Vokera boiler be?

The temperature can be set from a minimum of 37°C to a maximum of 60°C.

What does A01 mean on my boiler?

ignition failure
1. Vokèra Linea fault code 10 (Vokèra Compact code A01) This fault code suggests that there is an ignition failure with the boiler. You might also hear the boiler sparking up but failing to ignite. Potential fix: To fix this issue, your qualified engineer will aim to test the voltage going to the gas valve.

How do you reset a Vokera?

To reset your Vokera boiler, move the mode selector switch to the ‘OFF/RESET’ position and then move it back to either ‘hot water only’ or ‘heating and hot water’. Should this reboot get your boiler working again then you’ll know because there will be a constant green light.

How do you turn on the heat on a Vokera boiler?

LIGHTING THE BOILER Turn the mode switch to the ‘heating & hot water’ position. The status indicator should be ‘Green’ if the status indicator is flashing ‘Red’ refer to 3.2. Refer to the particular instructions for the type of time clock or control fitted and ensure there is a demand for heating.

What should the pressure be on a Vokera boiler?

between 1 and 1.5 bar
The pressure gauge shows the current pressure of the system, the gauge should be set between 1 and 1.5 bar. When the appliance is operating the gauge may rise or fall slightly, this is quite normal. The minimum permissible level for the safe and efficient operation of the appliance is 0.5 bar.

What does a red light mean on a Vokera boiler?

#1 – Red Light On, But Green Light Is Off A fan that doesn’t fire up during the start-up sequence, so the boiler is unable to expel flue gases. The pump isn’t circulating hot water, so hot water stays in the heat exchanger. The high limit thermostat has caused a lockout – your boiler is overheating.

What does A07 mean on boiler?

Faulty NTC Thermistor: Error code A07 If the differential is exceeded, the boiler displays the error code A07 and locks out. The common cause of this problem is a fault in the circulation including: Faulty pumps. Incorrect pump installation.

What does a red light on a Vokera boiler mean?

lockout
A Vokera boiler flashing red is likely due to a lockout, which will prevent heating and hot water working in your home. There a number of reasons why your Vokera boiler’s light is flashing red and one of our Gas Safe engineers can help quickly resolve this issue.

What should boiler pressure be?

between 1 and 1.5 bars
Boiler pressure should generally be between 1 and 1.5 bars when central heating is turned off. The needle of the pressure gauge should remain above the lower limit set by your boiler manufacturer at all times.

Categories: Most popular